021-57842298
Products
Current Location:
DV/DT Filters
❤ Add to collection

DV/DT Filters

0.00
¥0.00
¥0.00
¥0.00
Weight:0.00KG
Quantity:
(Inventory: 99999)
Buy now
Add to cart
Description

Functions and Application (dt/dv filters applied to cables over 100m in length)
The DV/DT filter protects your servo motor by minimizing the peak voltage that occurs at the motor terminals. It also offers maximum protection for cables and motor windings from premature aging or dielectric breakdown. All these result in extended motor life, improved reliability and uptime. The use of an electrical filter also minimizes electromagnetic interference to adjacent equipment, power or signal circuits, reduces current leakage that might occur in the ground wire, and attenuates the interference as the contactor between the filter and the motor is switched. This DV/DT filter design meets the output voltage requirements of IEC 60034-17, 60034-25.

Normal Cable Parameters (without Input Reactor)

Power 

rating 

(KW)

Max. 

current

(A)

Main cable 

(UL AWG)

Rated Inductance

Rated capacitance

 (conductor to conductor)

Rated capacitance

 conductor to 

conductor & shield

Rated Conductor

 DC Resistance 

@20 °C

Max.

 Recommended 

Current

@30 °C (Amps)

(Uh/ft)(Uh/m)(H/Km)(pF/ft)(pF/m)F/KM(pF/ft)(pF/m)(Ohm/1000ft)(Ohm/1000m)
5.512.8AWG140.2130.6996.988189E--042375.57.545932E--0842137.82.528.26825
1124.8AWG100.1840.6046.036745E--042995.19.514436E--0853173.90.9893.24540

The output dt/dv of a VFD is 3000V/μS. According to the power distribution parameters of a shielded cable, the critical length of traveling wave reflection is about 15m. If the cable is less than 15m, the output reactor can be spared.

Due to the inconformity of the distribution parameters of cables in the engineering industry, the output dt/dv of a servo motor is much larger than 3000V/μS, so it is advised that reactors with 1% voltage drop should be used if the cable length is more than 10m.

Differential Mode Test Data 

Switch frequencyTest point50m unshielded cable150m unshielded cable500m unshielded cable
UbusUpeakdv/dtUbusUpeakdv/dtUbusUpeakdv/dt
4KHzDrive output525603227552558822185256032394
Fliter output537594635286099852874469
Moter side5015647050157010943869679
8KHzDrive output528603235352859422155256032275
Fliter output525573685286159152574469
Moter side5015378149858210141467282
Without dt/dv filters, the peak voltage at motor terminals can reach over 1000V. (Cable length: 100m )

Common Mode Test Data

Operating current(A)LoadCM voltage(V)CM current(A)
53813
7680%275.51.9
CM Test Date of 95A dv/dt filter (Cable length: 100m )